PXIe-6672 Chassis compatibility list

Could you please provide me a list of Chassis with the specific casing for timing module PXIe-6672 (usually installed on slot 10 of Pxie-1075, Pxie-1085 & Pxie-1095?I'm using Pxie-1095, but I would...

View Article


Obsession with PXI

A discussion I had with a BFT club owner late last year on why they don’t tell members the PXI in advance, is because they don’t want you to do the prescribed minimum. The idea is to give your best...

View Article


Aligning counter input with analog input on PXI-6229

I am trying to read in a handful of analog input measurements along with two counter input measurements. I was able to set up, acquire, and log the analog inputs just fine. However, I keep running into...

View Article

PXIe-4138 pulse width is consistently 80ms ~ 120ms longer than configured

I'm using an NI PXIe-4138 module in a PXIe-1073 chassis, trying to generate a 50 µs current pulse. I'm measuring with a 1X passive probe connected directly across the SMU output terminals, with no load...

View Article

Tester SMU 4147 Self-Calibration Failing

The tester is experiencing a recurring issue where one specific SMU is failing self-calibration. I tried running the self-calibration routine on this individual SMU separately, but it continues to...

View Article


DC Continuity - Failing in Verify IDPROM

I am currently performing DC Continuity for P143 (DMM-4081, PPS-4110) and always failing in Verify IDPROM in different resource everytime. I already tried replacing DMM-4081, PPS-4110, P143 Cable and...

View Article

PXI-6562 used board

Hi, I would need 1 or 2 Pcs used PXI-6562 LVDS Board. Is there someone who would sell these to me? Please contact to me a.s.a.p. jussi.tuppurainen@oitec.fi Thanks a lot, BR : Jussi

View Article

PC will not recognize NI PXIe-5105

I currently have a NI PXIe-5105 hooked up to a PXIe-1071. The PXIe-1071 seems to be running fine, but for some reason, the PC will not recognize the PXIe-5105. In NI MAX it just states "Not Present"...

View Article


PXIe-1082 won't power on

Hi, I have a PXIe-1082 chassis with a PXIe-8398 remote control module and a PXI 6133 DAQ. It's been working fine. I went to turn it on today and there's no response. The breaker does not appear to be...

View Article


PXI-2546 - Relay count exceeded rated life: replacement vs. soft count?

Hi all,We have three NI PXI-2546 RF multiplexer cards in a production test system, and all three are now reporting that their expected relay life has been exceeded for both the mechanical and...

View Article

PXIe-8821 NIMax issue

Hi everyone.  I've been pushing this problem for a few days now and am stuck.  I've got a PXIe-8821 controller that should be running LinuxRT.  It keeps booting in safe mode and doesn't seem to have a...

View Article

Which has improved performance on PXI RT-Target OOP or regular LabVIEW

Hi Community, We plan on creating a measurement and control system with a PXI-RT-target at its core.Until now I used classic LV producer consumer/Statemchine architecture to set up such a system. A new...

View Article

Thunderbolt issues

One of our custmer has purchased a PXIe 1090 with PXIE6723 card and we are trying to connect the same with a thunderbolt connection through a ASUS PC/System. While windows recognizes the PXIe 1090...

View Article


Different PXI 5775 Model Differences

 We are looking to buy a new PXI 5775 for our measurements. We are deciding between 785592-01 and 785591-01. Could you elaborate on the differences between FPGA Kintex UltraScale KU040 and KU060? What...

View Article

PXIe1084 chassis status ledswitching to solid red color

Very recently (from last 2 weeks), I'm facing issues with PXIe-1084 chassis status led switching to solid red. It is recovering only, after I manually power it off, wait for 10secs and power it on....

View Article


to grab PXI 4137 current pulse transient profile with internal Digitizer

Good dayI am using PXI 4137 current pulse mode to measure LED voltage, adjusting SourceAdapter parameter with DSO, Is it possible that grab the pulse transient profile with internal Digitizer rather...

View Article

Reliability/MTBF Data for NI Devices

Does NI have Reliability/MBTF data for any of the following devices, and if so can the info be shared? PXIe-1095PXIe-6738PXIe-4331PCIe-8431/2PXIe-4081PXIe-2527PXIe-6612 Also does NI have a Counterfeit...

View Article


192061-02

Hi, Can somebody answer what is the outer diameter of 192061-02 cable.

View Article

Calibration of the PXI-5610/5441/5671

As the title suggests, I am trying to find any information on the 5610, the 5671, and 5441. It seems all of these have been wiped from the website recently, there are a lot of page not found/deleted...

View Article

Hazardous voltage error (PXIe-4136) after self-calibration

Ever since I performed the self-calibration in NI-Max for the SMU PXIe-4136 (the self-calibration was successful), I get the following error as soon as I try to output a voltage:...