Quantcast
Channel: PXI topics
Browsing all 3416 articles
Browse latest View live

PXIe Bandwidth for FPGA

Hi,I am testing the peer to peer stream bandwidth of PXIe-1082 by using Labview 2018 with an FPGA FlexRIO system. According to Labview 2018...

View Article


PXI 2529 NI Switch Topology

In Testand I initialize in the setup the DMM then I would like to initiate NI switch. I always get the error code 1074118655 and the detail says: niSwitch Initialize With Options.viAnother process has...

View Article


Image may be NSFW.
Clik here to view.

Controller P2P bandwidth

Hi all,I tried to measure the peer to peer streaming rate of PXIe-1088 by using FPGA system with Labview 2018.I use PXIe-5785 as writer, PXIe-7976 as reader, representation is I16 and write 8 data into...

View Article

PXI CONNECTOR

What's the difference between NI 6555 and NI 6542 pxi connector ? how to choose?

View Article

PXIe-7975 FlexRIO Adapter Module Current Draw

Hi All,I am currently designing a FlexRIO adapter module for a PXIe-7975 and need to know how much current I can draw from the +3.3V and +12V pins on the edge connector, however I can not find any...

View Article


PXI-6723 error code: 50400 in MAX

Hi, I am having trouble with the PXI-6723 card in MAX. It was in a hybrid slot of PXIe-1073 Chassis, which was installed by factory before shipment. I can find the card on device manager and MAX. But...

View Article

working with the same session of a DMM 4065 in the whole python code with...

Hello everybody,I would like to have your help about how can we use lock() (NI modular Python API) to work with the same session of a DMM 4065 in the whole python code with different methods...I do...

View Article

Amount of DAQmx channels

hello everyone, I have a channel selector and can select multiple channels. The datatype of this control is 'DAQmx- physical channel'. Is there a property node for the amount of channels select?

View Article


Software intalled, indentified MAX, cannot find PXI-7813R in the project

Hi, I'm having a small problem with adding the FPGA target.I think the software is installed, versions are matched, and the connection has no problem, MAX even shows nice detection of the devices. But...

View Article


Image may be NSFW.
Clik here to view.

How to connect PXIe-5162 by Matlab?

Hi,I try to control my NI PXIE-5162 using the Ni Scope and Matlab Instrument Control Toolbox. Ni Scope can connect it. But Matlab cannot connect it. After conducting the command 'connect(ictObj) ' ,...

View Article

test post

This is just a test message

View Article

PXIe-4300 for Single ended measuerment

Hi All, I have one question regarding PXIe-4300 to use it as single ended measurement.is it possible to use it as 16 channels single ended???  

View Article

Accelerometers and cDAQ manipulation

Hello, I have a question regarding accelerometers interfacing with the compact DAQ system. If I'm using two triaxial accelerometers along with two 9234 modules, can I take one input (let's say the...

View Article


anti-aliasing filter calculation

Hello,I would like to connect instrumentational amplifier to one of the analog inputs (in RSE mode) of the PXI-6259 DAQ. Im wondering how to optimally choose values for Rf and Cf of an anti-aliasing...

View Article

PXI 2597

Hello everyone, I am currently using PXI - 2597 with Labwindows CVI, but I could not find the driver of the switch.  Could you help me? Thanks a lot. Best regards.

View Article


Transmit signal from PXIe-6341 to PXIe-7962R

I am designing a scanning image system. PXIe-6341 and PXIe-7962R are on PXIe-1073. PXIe-6341 is used to collect the trigger signal from pin AI0; PXIe-7962R is responsible for processing image data....

View Article

PXIe-6363 Multifunction DAQ Card Not Showing Up in NI-MAX

I have installed a PXIe-6363 module in a PXIe-1078 chassis with a PXIe-8821 control module. I have also installed various other modules. I see all the other modules when I look at the PXIe chassis in...

View Article


PXI-1044 Causing PC Failure

Hello everyone, Problem;I am experiencing an issue with one of my PXI-1044 chassis. Upon startup with this the PXI chassis on, when trying to boot the computer the computer fails to start but instead...

View Article

NIdigital waveform generator/analyzer

We are planning to use NI 6555 and NI 6542 ,for performing dynamic acquisition and dynamic generation with our customized board. what type of interfacing cable we can select for this , what are the...

View Article

PXI 6555 / PXI 6542

We are designing a custom board to interface with "NI PXI -6555 /6542". I am using the connector HDRA-EC68LFDT2 to interface with NI modules. Kindly confirm if this is acceptable and also suggest the...

View Article
Browsing all 3416 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>