NIHSDIO Error
As shown in the Figure,I wanna generate the signal in the red box at the DIO of PXIe-6548,but it appears an error,How do I fix it, or am I wrong?
View ArticleSCC-68 with 6341
I can't have access to the configuration of the scc-68 module, i have 2 relay module on module 1 and 2 but can't modify anything Maybe something missing in daqmx. cf picture
View ArticleSetup PXI-1042 Chassis with PXI-8360 and PCI-8361
I have tried to setup a PXI-1042 Chassis with PXI-8360 and PCI-8361. I have installed all software listed in attachment 'treiber calib pc.PNG'.When I open NIMAX, only the PCI-8361 Card is listed in...
View ArticleProduct Life Cycle Status
Is it possible to find out how long a certain instrument will be avaliable for purchase, repair, replacement?I need this information to plan the spare parts I need. I have the following instruments in...
View ArticleConnection from PXI-8186 to USB
I use PXI-8186 and LabView-2010. I have third party devices with USB-interface.Can the PXI-8186 processor operate via a USB interface by VISA subVI ?I can work with USB devices connected to a Windows...
View ArticleKeysight M3201A causes NI-MAX issues
I am seeing a problem when I use a Keysight M3201A PXI AWG and I was wondering if someone might have some thoughts on what may be causing this. I found that my tester containing this instrument was...
View ArticlePXIe-6345 Multifunction IO Module and Digital Pattern Editor
Is Digital Pattern Editor compatible with PXIe-6345? In particular, I want to use the PXIe-6345 analog inputs to measure voltage, and I want to look at the results in the Pin View window of the Digital...
View ArticleTwo PCs connected to a single PXI chassis
I couldn't find anything on this topic.So, we have a PXI Chassis with some instrumentation sitting in the lab and we would like to be able to access the PXI Chassis from two separate PCs, one a the...
View ArticlePXIe-1073 Programmatically Power Off Chassis
Hi, I am looking for a way to programmatically turn off/shutdown a PXIe-1073 chassis that is connected to our host PC running windows 11.Looking under Measurement I/O --> System Configuration...
View ArticlePXIe-6341 is not detected by NI Max
Hi, There is an issue with the PXIe-6341 module that we use for I/O in our multiphoton imaging system. Apparently, the PXIe-6341 module is not detected by the NI Max software and also the "LINK" LED in...
View ArticlePC to use with PXIe-8301 Thunderbolt
Hello, I am looking for any PC with Thunderbolt that was tested to be compatible with PXIe-8301. In my setup (Dell Thunderbolt 4 Networking Card in Dell Tower Precision PC) PXIe system configures...
View ArticleNI Embedded Controllers Export Classification for PXIe chassis's
Do any or all of the PXIe embedded controllers NI offers with a classification of 5A992.c meet or exceed the performance parameters in 3A090 or 4A090?
View ArticleWorks a PXI 5401 in a PXIe System?
Is it possible to use a PXI 5401 card in a PXIe-System like 1083?
View ArticlePXIE-4190 LCR Open & Short Compensation
Result we obtained on our measurement setup after passed through a customized PCB : No apply compensation = 23.586pFApply only short compensation = -15.167pFApply only open compensation = 14.131pFApply...
View ArticleSetup to turn ON PXIe-1073 Chassis with PCIe-8363
Sorry for the ignorance. Analyzing the PXIe-1073 User Guide and I didn't understand how to configure it:I'm looking for a way to automatically turn on, without pressing the ON/OFF button, a PXIe-1073...
View ArticleShutting down PXI-1042
Hello, I have a PXI-1042 with a PXI8840 controller running on windows. When I shutdown window the controller 'shuts down' but the chassis keeps running and I physically require to press the power...
View ArticlePCIe-8398 data throughput enough to remove NI RAID chassis
Hello! I am looking to upgrade our system to some more modern hardware, and one of the things I'd like to do is get away from the NI branded RAID chassis, as it has given us some issues in the past....
View ArticlePXI-5105 digitizer timing out
Hello, I am using a PXI-5105 in a PXI-1033 chassis. When trying to acquire data in NI-Scope, there is a timeout error status code -228858 (see attached picture). The attachment to the PC is with a NI...
View ArticlePXIe-4081 DMM Driver for RHEL 32Bit
Have a PXIe-4081 DMM card.Due to the architecture need to have 32 bit for RHEL7.Do these drivers exist or supported for the PXIe-4081? Thanks in advance
View ArticlePXIE 8861 will support Windows 10 OS?
PXIE 8861 will support Windows 10 OS?what is procedure to install windows 10 OS.I don't have Windows OS.
View Article