ExportedSampClk.Mode and ExportedSampClk.Delay

Hi, I'm using a Pxie-6548 which is connected to the CB/SCB-2162 thanks to a C68-C68-D4 cable.I am doing an easy test, just generating from channels 25 to 30 and acquiring from channels 18 to 23 while...

View Article


Experiencing increased channel noise levels on PXIe4497 with 1071 fan on HIGH

I am using a PXIe-4497 to collect microphone data and when I switch the PXI chassis 1071e fan to HIGH setting, the noise level increases.  The chassis is outside of an isolated test chamber, so the...

View Article


Experiencing increased channel noise levels on PXIe4497 with 1071 fan on HIGH

I am using a PXIe-4497 to collect microphone data and when I switch the PXI chassis 1071e fan to HIGH setting, the noise level increases.  The chassis is outside of an isolated test chamber, so the...

View Article

pxie-5186 front panel label

Do anyone know where I can get a replacement front panel label for a PXIe-5186? Ive got one that has a bid gash in it and it looks terrible. the card works just fine. the front of it just looks real...

View Article

Can I PLL the PXI-6115 master timebase to the PXI_CLK10 exported by PXI-6652...

System Components:PXI-1036 chassis connected vi MXI-Express to a laptopPXI-6652 Timing and Synchronization Control modulePXI-6115 S-Series Multifunction DAQPXI-5412 Function Generator I want to use the...

View Article


PXIe-4330 Remote Sense

I'm trying to get the remote sense on the PXIe-4330 to work. I've have a bridge based sensor connected as the manual shows it. I cannot find a property node that enable the remote sense. Does the...

View Article

PXI MTBF

Hi,I am looking for the MTBF of the following references:- PXI-8119- PXI-6713- PXI-4071- PXI-6511- PXI-6512- PXI-6513 Thank you for your help, 

View Article

I have a PXIe-8381 board that is no longer being found in the system. I have...

This system has worked for several months but now is not being found in the automation explorer. As stated the front panel of the module has a blinking red light.  It looks like the led on the express...

View Article


pxi-5122 vs pxi-5122ex

what are the differences between the PXI-5122 and PXI-5122EX? does the EX have the same functionality as the non-EX, but with additional functionality? is the EX a drop in replacement for the non-EX?...

View Article


PXImc Desktop Target Hardware Configuration

Hello NI Users, I would like to build up a testbench by using PXImc with an PXIe-chassis (1082) and a Desktop Target (PCIe-8381), both running Pharlap ETS 13.1. Unfortunatly I need a special hardware...

View Article

Can MXI-4 cables be daisy chained?

I want to connect two 5m MXI-4 cables end to end.  Is that possible and would it degrade signal integrity?  I have a PXI chassis inside a large system and the MXI cable is routed through the system to...

View Article

NI power quality analyzer

HelloI have to build power analyser such as "voltech PM 600" using labview,I have gone through the power quality analyzer tool kit can i use it for the same?any heads up on how to start? 

View Article

capacitance of cable - SH6868

Hello ,I am using cable SH6868 - 182419-01 in my project. I need the capacitance of this cable as i couldn't find in the data sheet.So that, i can select op-amp buffer which can drive the cable...

View Article


Shorting PXI-7854R DIO pins together

We're building a self test fixture for PXI-7854R FPGA card.  We'd like to connect two DIO pins directly together to perform a "loop back" test to verify FPGA card itself, as well as the wiring and...

View Article

Should PFI I/O Be Set To A Default Setting Before Use?

Hi everyone, I am using the PFI lines on my PXI DAQ Card (6229) for Counter Output frequency generation and Counter Input frequency readings.  I know these lines on power up of the PXI card are set to...

View Article


PCI6703 AO adjument

我在根据《NI 6703/6704 Calibration Procedure for NI-DAQmx》做6703的外部校准,使用Labview运行环境。其中第8步, Repeat step 4 through 7 replacing AO 0(V)with  _cal_ao_voltage_offset .Continue to repeat step 7 with various values...

View Article

Windows 7 Upgrade

We have completed a Windows XP to 7 update with a PXI-8108 and getting a dxgkrnl.sys BSOD error peridically. Anyone have an experience with this? Or updating to Windows 7?

View Article


help me ni5661 am-ssb demodulation example?

hi my friends i`m a student i need help to make demodulation am-ssb  and listen the modulated signal on speaker > i`ve ni-5661 rfsa plz i need an example for this. thanks all

View Article

how to read only value change data in XNET CAN ?

Im dealing with some thousand CAN signals and i want to read only the value change data in XNET CAN. Please give some solutions.

View Article

installation win 7 profesiona| 64 bit on ni pma 1115

i want reformat my pxi from win xp to win7 64 bit... but i cant boot up the win 7 installation which is usb flash storage...the usb flash is work fine with laptop which it can be boot up and install...