Troubleshooting SCXI
In the Measurement & Automation Explorer (version 4.5.010) I can see "PXI System (Unidentified)" and under that I see "PXI6::9::INSTR (PCI-6220)" and nothing else. In the SCXI-1001 Chassis I have...
View ArticleSynchronization of signals from 6251 and 4330 cards
I am student at IIT Kanpur. In my thesis, I am acquiring data from Hot Wire and 2 strain gage pressure sensors simultaneously. I am using a NI PXI 1073 chassis and NI 6251 for hot wire and NI TB 4330...
View ArticlePXI 1033
Friends, Can anyone explain me difference between a DAQ card and a PXI controller unit. I know what is a DAQ and have been working on one but one of our new instruments came with a PXI-1033 unit and...
View Articlepxi 2575 - 2 wire resistance measurement
Does anyone know why the 2575 is not recommended for 2-wire resistance measurement? thanks
View ArticleDigital Multimeter Measurement Cycle for PXIe-4080
Hi, I am looking at the measurement defaults for the DMM instrument, PXIe-4080, similar to the page that I found here "http://www.ni.com/product-documentation/3294/en/#toc2" But, from reading, the page...
View ArticleMoving files out of the PXI trivial
We have a NI PXI-8184 that boots up with no windows and runs the labviw exe. Test data is saved to the PXI and every few months we back up/move the test data to another location on the network using...
View ArticlePower button event
Does PXI chassis log if power button was used to power it off?Is that event accessible in RT?
View ArticlePXIe-5413 maximum DC Offset
Hi!I upgraded my PXI system from the PXI-5402 waveform generator to the new dual channel AWG PXIe-5413. Unfortunately I discovered that the DC offset for this last is only 50% of amplitude despite a...
View ArticlePXI HSDIO 6552 Added Memory changes identity of device but functions correctly
I removed a memory board from a PXI 6552 (HSDIO device) with only 8 Gb/channel and replaced with a 64 Gb/Channel board from a PXI 6551. Functional tests including loading and unloading the memory at...
View Article10 MHz ref CLK in pxie 5170 module
Hello I want to use pxie 10MHz CLK in my FPGA code as IO port, but this CLK isn't accessible. what should I do to accessing this CLK?
View ArticleAnalog Input Anti-Aliasing Filter PXI-6123
My apologies, I think I may have posted this incorrectly at first in the Multifunction DAQ board. I am currently using a BNC-2110 to connect, monitor, and log dynamic pressure transducers (4 analog...
View ArticleWindows PXI not listed in 'add targets and devices'
I have a pxi system that is currently running windows.Can I access and deploy a project from a 'remote' labview environment? When I install a Real-Time os on the pxi system, I am able to select...
View ArticleJackpost information for PXI adapter
This may be the wrong location, its a little more 'hard' than 'ware'. I am not able to find a drawing of NI 187949-10. I am making a custom breakout adapter for an SHC68-68-EPM type cable. The...
View Article6674T not detected when trying to sinc 2 chassis (both with a 6674T)
Hi all, I have a problem when I try to sync the 2 PXIe 1085 chassis. Both of them are equal, they have a timing card 6674T in the slot 10 and 3x5645R (ports 2, 6 and 11). Each chassis works fine...
View ArticleLetter of Volatility for HDD-8261
Hello, Not sure where to post this as I did a pretty thorough search on this topic for this specific hardware component. Looking for any information pertaining to the volatility of the HDD-8261 to...
View Article5646R Calibration Execuitve 4.1.1 "Adjust LO Power Sensor" Error
During adjustment "Adjust LO Power Sensor", Calibration Executive displays a fatal error stating that the program "could not converge upon a single value". The error is repeatable for every VST unit...
View ArticleNI PXI-5124 High Speed Digitizer, Timing Issue, don't have Extract Single...
Hello, So I am trying to complete a verification on a PXI 5124.I do not have the full development version of labview, just the basic development version.I am trying to complete the timing checks as in...
View ArticleIs there a chance to install Windows 10 (64-bit) on a PXI-8108?
I am facing the request that the operating system on a PXI-8108 needs to move to Windows 10 (on account of a company rule). Has anyone already done so? Do I have to expect any issues?
View ArticlePXI-4071 Feature: DC Noise Rejection. Different between modes ?
Hello everyone! DC Noise Rejection has 3 mode (Normal, second-order, high-order). In the description described that all of they are differing the relative weighting. And shown the graphic with...
View ArticleXNET to send CAN message at variable a rate PXI 8512
I have managed to set up PXI 1082 chassis with PXI 8512 CAN card with 2 ports linking together. So that I can write to CAN1 and read on CAN2 to verify what I have written. (See attached Loopback Test...
View Article