Troubleshooting SCXI

In the Measurement & Automation Explorer (version 4.5.010) I can see "PXI System (Unidentified)" and under that I see "PXI6::9::INSTR (PCI-6220)" and nothing else. In the SCXI-1001 Chassis I have...

View Article


Synchronization of signals from 6251 and 4330 cards

I am student at IIT Kanpur. In my thesis, I am acquiring data from Hot Wire and 2 strain gage pressure sensors simultaneously. I am using a NI PXI 1073 chassis and NI 6251 for hot wire and NI TB 4330...

View Article


PXI 1033

Friends, Can anyone explain me difference between a DAQ card and a PXI controller unit. I know what is a DAQ and have been working on one but one of our new instruments came with a PXI-1033 unit and...

View Article

pxi 2575 - 2 wire resistance measurement

Does anyone know why the 2575 is not recommended for 2-wire resistance measurement? thanks

View Article

Digital Multimeter Measurement Cycle for PXIe-4080

Hi, I am looking at the measurement defaults for the DMM instrument, PXIe-4080, similar to the page that I found here "http://www.ni.com/product-documentation/3294/en/#toc2" But, from reading, the page...

View Article


Moving files out of the PXI trivial

We have a NI PXI-8184 that boots up with no windows and runs the labviw exe. Test data is saved to the PXI and every few months we back up/move the test data to another location on the network using...

View Article

Power button event

Does PXI chassis log if power button was used to power it off?Is that event accessible in RT?

View Article

Image may be NSFW.
Clik here to view.

PXIe-5413 maximum DC Offset

Hi!I upgraded my PXI system from the PXI-5402 waveform generator to the new dual channel  AWG PXIe-5413. Unfortunately I discovered that the DC offset for this last is only 50% of amplitude despite a...

View Article


PXI HSDIO 6552 Added Memory changes identity of device but functions correctly

I removed a memory board from a PXI 6552 (HSDIO device) with only 8 Gb/channel and replaced with a 64 Gb/Channel board from a PXI 6551.  Functional tests including loading and unloading the memory at...

View Article


10 MHz ref CLK in pxie 5170 module

Hello I want to use pxie 10MHz CLK in my FPGA code as IO port, but this CLK isn't accessible. what should I do to accessing this CLK?   

View Article

Analog Input Anti-Aliasing Filter PXI-6123

My apologies, I think I may have posted this incorrectly at first in the Multifunction DAQ board.  I am currently using a BNC-2110 to connect, monitor, and log dynamic pressure transducers (4 analog...

View Article

Windows PXI not listed in 'add targets and devices'

I have a pxi system that is currently running windows.Can I access and deploy a project from a 'remote' labview environment? When I install a Real-Time os on the pxi system, I am able to select...

View Article

Jackpost information for PXI adapter

This may be the wrong location, its a little more 'hard' than 'ware'. I am not able to find a drawing of NI 187949-10.  I am making a custom breakout adapter for an SHC68-68-EPM type cable. The...

View Article


6674T not detected when trying to sinc 2 chassis (both with a 6674T)

Hi all, I have a problem when I try to sync the 2 PXIe 1085 chassis. Both of them are equal, they have a timing card 6674T in the slot 10 and 3x5645R (ports 2, 6 and 11). Each chassis works fine...

View Article

Letter of Volatility for HDD-8261

Hello, Not sure where to post this as I did a pretty thorough search on this topic for this specific hardware component.  Looking for any information pertaining to the volatility of the HDD-8261 to...

View Article


5646R Calibration Execuitve 4.1.1 "Adjust LO Power Sensor" Error

During adjustment "Adjust LO Power Sensor", Calibration Executive displays a fatal error stating that the program "could not converge upon a single value". The error is repeatable for every VST unit...

View Article

NI PXI-5124 High Speed Digitizer, Timing Issue, don't have Extract Single...

Hello, So I am trying to complete a verification on a PXI 5124.I do not have the full development version of labview, just the basic development version.I am trying to complete the timing checks as in...

View Article


Is there a chance to install Windows 10 (64-bit) on a PXI-8108?

I am facing the request that the operating system on a PXI-8108 needs to move to Windows 10 (on account of a company rule).  Has anyone already done so?  Do I have to expect any issues?

View Article

PXI-4071 Feature: DC Noise Rejection. Different between modes ?

Hello everyone! DC Noise Rejection has 3 mode (Normal, second-order, high-order). In the description described that all of they are differing the relative  weighting. And shown the graphic with...

View Article

XNET to send CAN message at variable a rate PXI 8512

I have managed to set up PXI 1082 chassis with PXI 8512 CAN card with 2 ports linking together. So that I can write to CAN1 and read on CAN2 to verify what I have written. (See attached Loopback Test...

View Article