Drive PXI Backplane Trigger w/ Digital Input from PXI-6528
I have an MXI chassis which outputs a digital signal. This is wired to a digital input on a PXI-6528. I would like to drive a PXI backplane trigger with this input which itself will then trigger an...
View Article4135 SMUs test problem
Hi, I test the MOS and BJT by two 4135 SMUs, but I found the test method of "hardware-timed two channel voltage sweep" is different Keithley 4200, that is when I set the current limit is 10 mA,...
View ArticleHow to solve Error 250043 when synchronizing pxie 5423 and 5105
When I synchronize PXIe-5423 and PXIe-5105 with NI-TClk, an error 250043 usually occurred, and the error details are: Error 250043 usually occurredat niTClk configure For Homogeneous Triggers. vi:...
View ArticleAbout the trigger aquisition problem of the PXIe-5162
I have a PXIe-5162 board, and then what I need to set in NI-Scope so that I can start data collection when the external trigger signal arrives, and collect the amount of data I set in advance.The...
View ArticlePXIe-1062Q
PXIe-1062Q is it available anywhere in Pakistan where i can test my program...
View ArticlePXI 4071 aborting reads
Hello, This question is in regards to aborting asynchronous reads on the PXI-4071 digital multimeter. I've been struggling for awhile to understand how abort is supposed to work. I'm currently using...
View ArticleRegarding RAID NI HDD 8265
I have one HDD 8265.I have installed all drivers and set up with the help of http://www.ni.com/tutorial/53938/en/#toc5 .The actual write speed is 750 MB/s but i am writting at the speed of only...
View ArticleNIFPGA Python Library FIFO Read/Write Flow Control
I'm trying to use the nifpga library to read and write to the FIFO on an NI FPGA (PXIe-7856). The size of the data I am working with is 32 elements, and every time I change the input values (lets call...
View ArticlePXI DMM 4071 DC current measurement accuracy
Hi team, I'm using PXI DMM 4071 to measure a DC current, and meet a problem with the result accuracy. When current range is set to 1A, the measurement result is 0.015785, when current range is set to...
View Articlewhy am I seeing three ethernet ports for PXI
Hi,I am using PXIe-8135 for quite a long time. I am facing issues in its ethernet port, getting disabled automatically. My PXI is connected to network using both ports for redundancy purpose. I have...
View ArticleTrigger Lines for PXI-2530 in Chassis 1045 not visible
Hi,I have 4 PXI 2530 Multiplexers in a 1045 ChassisI would like to use handshaked scanning with PXI 4072But it Fails!There are not Trigger TLL0-7 Support for 2530 Whats wrong?Using latest Drivers....
View ArticleTrigger Lines for PXI-2530 in Chassis 1045 not visible
Hi,I have 4 PXI 2530 Multiplexers in a 1045 ChassisI would like to use handshaked scanning with PXI 4072But it Fails!There are not Triggers TLL0-7 that shows support for 2530 Whats wrong?I am using...
View ArticleHow to update NI PXI 6570 specification file variable from LabVIEW without...
Hi, I'm loading a specification file (*.specs) to NI PXI 6570 Digital Pattern Instrument memory using the 'niDigital Load Specifications Levels and Timing.vi' (from niDigital APIs) from LabVIEW. I...
View ArticleMaximum voltage for PXI-5900 above ground/earth
I have purchased a PXI-5900 differential amplifier to use with a PXI-5922 so I can measure differential voltages floating above ground. The manual for the PXI-5900 has a description of :Common-mode...
View ArticlePXIe-8360, SM Bus Controller
I am having issue with one of the chassis not being recognized, I remember when installing both PXI chassis on another computer I was able to see both.Here is the snapshot of MAX and Device Manager.
View ArticleTB-4330 "Unsupported Accessory"
Hi,I have PXIe-1078 chassis with 5 PXIe-4330's and 5 accompanying TB-4330's. All of the TB-4330's work but one that is not properly recognized in Lab View and the Measurement and Automation Explorer....
View ArticleIs my chasis backplane compatible with new controllers?
Hi everyone, I have got the chasis NI PXI-1031 with the "pcb 260-01150" backplane and I would like to know if it is compatible with NI PXI-8840 (embedded controller) and NI PXI-8360 (remote...
View ArticleUsing Serial Comm Port of PXIe8135 RT in Veristand
I have signals that need to be sent and received over serial port to ECU from PXI. I dont have any serial card, how can use serial port in Veristand the way I use other IO channels to connect to system...
View ArticlePXI 5646R : Phase coherent
Hi NI guys !I'm trying to generate two sine waves with two PXI 5646R modules with the same frequency. It's pretty easy with the library Ni-RFSG. However, now, i need to have the same phase with my two...
View ArticleDoes PXI-5114 have seamless data logging capabilities at 125MHz?
I'm working to get a diagnostic up and running and I need a DAQ that can record a voltage signal that repeats on a 1MHz rep rate. (I am using a photodiode to measure the pulse-to-pulse integrated...
View Article