PXI - 8135 doesn' t turn on
Hello Good morning all, I am trying to set up a system for massive MIMO. I have got PXI-1085 chassis and a couple of other equipment for it. My problem is when I installed the PXI - 8135 controller...
View ArticleCan I connect PXIe-8375 to my laptop using ExpressCard?
Hi, Can please some one let me know whether can I connect PXIe-8375 to my laptop using ExpressCard? if Yes can please let me know the part number of that hardware. I tried to search for the solution in...
View ArticlePXIe read trigger timestamp for 'real' t0
I looked for a post that addressed my problem, but I couldn't find one that quite answered my question. Based on the below link, the timestamp returned by DAQmx from a `DAQmx Read` operation is...
View ArticlePXI-6683H is not syncing timestamps across multiple cards
In my system i have 3 PXI chassis that each are controlled by a PXIe-8880. Each PXI chassis has a PXI-6683H card. I have a Cisco IE 4000 setup as a PTP time source, which it connects all the 6683H...
View ArticleWindows 10 Activation on PXIe-8861
Has anyone had issues trying to activate Windows 10 on a PXIe-8861 controller?I received a PXIe-8861 four days ago and still NI has no clue on how to enable the digital license on this controller....
View ArticleNeed to generate 1kHZ in PXI 6515
Hi , how to determine the NI PXI-6515 card able to generate 1kHZ signal ?
View ArticlePXIE4139 同軸ケーブルを使用した際の使用方法
PXIE4139をオプションを付けて、同軸ケーブル経由で用いたいと思っています。 その際に同軸ケーブルのガードとPXIEのLOを物理的に接続して使用する予定です。コマンドで同軸ケーブルのガードとPXIEのLOを接続することは可能ですか? もしコマンドありましたら、本チケットに追記をお願いします。
View ArticleAun se puede utilizar la tarjeta NI PXI 4462? No esta descontinuado su uso...
Encontre una tarjeta la cual consegui hace un tiempo y queria averiguar si aun se puede utilizar con los nuevos software debido a que ya han lanzado nuevas tarjetas y las computadoras ya son diferentes...
View ArticleFLIR USB 3.0 Camera not detected by PXIe-8135
My Real-Time application requires the use of a FLIR Grasshopper3 USB 3.0 camera. I tried attaching it to all the available USB ports on my PXIe-8135, but my camera failed to show up in NI-MAX for every...
View ArticleBNC
Hello, I have a BNC-2110 and a desktop computer that doesn't have a NI PICe-8361. Could anyone tell me if there is a way to connect the BNC to the computer without having to use a PXI? I need a simple...
View ArticleHost isn't starting with a NI PXIe-1073
I have a PXIe-1073 (with a PCI-5122 in peripheral slot 3) attached to the host computer via MXI. The host turns on with the PXIe turning on, as expected, but the host computer appears to be stuck in...
View ArticleLV-222-555-000 mil-1553 with Labview on Linux
Will this work, or is it a 15k paper weight now? I didnt see anything about this being windows only when ordered but maybe I missed it.
View ArticleGet Relay Position - Software or Hardware?
Hi, Are the commands to get the Relay Position (both Swtich and DAQmx deprecated) done by software (last command sent) or is there a physical verification?Can that be used to verify if a relay is fused...
View ArticleContradictory info about PXI-4110 & PXIe-1078 interoperability?
Hi, I am new to the NI environment (and data acquisition, really) and I'm trying to pick the components for my first PXI system. With the positive and negative 20V outputs the PXI-4110 (with...
View ArticlePXIe-4112 error code
I'm using a PXI-e 4112 power supply and I'm getting error code 1073364992 - anyone know what this means?
View ArticleDigital Pattern Editor with PXIe-6570 Error
Hello! This simple single-frame SPI pattern was working for me previously and just started breaking with no change. Any idea why this error is happening? It says I need a capture_stop, but I do have...
View ArticleConnecting PXI-8880 to Labtop via Ethernet
I'm trying to connect my laptop to a NI PXIe-8880 controller (via ethernet) to be run remotely. I did not have an operating system installed, hence the need for the laptop. I've connected the laptop to...
View ArticleSetup LIN as slave on veristand
How to setup Veristand setup as LIN slave device? How to make veristand setup respond to the master LIN header messages?Please point me the resources if any.
View ArticleIP Address: 192.168.1.XXX vs. 169.254.180.XXX
A highly knowledgeable consultant suggested that I change the IP address on my PXI system from 169.254.180.XXX to 192.168.1.XXX. He said that this would change the IP address to a static address and...
View ArticleRemote Control of PXIe-8880 Controller
I'm trying to connect my laptop to a NI PXIe-8880 controller (via ethernet) to be run remotely. I did not have an operating system installed, hence the need for the laptop. I've connected the laptop to...
View Article