I am using PXIe 5645r for RF Signal generation. I am using script mode for waveform generation. I want to get I-Q out along with the RF out from single module for same parameters. Can we do that?
PXIe-5645r Configuration
PXI-2567 5V tolerance?
hello,
I would like to know the tolerance of the 5V of PXI-2567 that is obtained from pin 58. Wasn't able to find the same in the datasheet.
Regards,
Naveen
False LIN-communication PXI-8516
Hello Everyone,
This is my first question here, actually i have a big issue with LIN Card Communication, my program is devolped in LabVIEW, but only ocacionally does it stop working and it fail to communicate.
The PXI has wiring around 1 meter to the test card.
Did some of you support collages?
AIT 1553 RT support
we tried developing a project in labwindows realtime.Ni daq is working fine in this project.we tried AIT1553 ,though build succeeds at run time it is showing the following error
if we continue it is showing the following error
we have checked the software installed in host and target and r both same 2.54.2
We are using Labwindows 15 and LabviewRT Run time engine 16
Can anybody help to resolve this problem.
Regards
Preetha
Calibrating PXIe-4353 with CAL-4353 and Fluke Calibrator
I am using a Fluke 5500 Calibrator and the CAL-4353 to attempt the calibration of some NI PXIe-4353 cards. I am trying to follow the calibration procedure, but am running into some road blocks. The first problem is I can't "calibrate" the unit. I go into NI Max and find my unit. When I right click on it to configure, it reads the CAL-4353, but everything is grayed out and I can't execute the calibrate function. The other problem that I am having is I don't know where the SC Express Calibration Accessory Channels VI are recalled from. The procedure states " Call the DAQmx Connect SC Express Calibration Accessory Channels VI. Configure the CAL-4353 by setting the connection to _tc_calibration and the physical channels to Dev1/ai0:31". Throughout the procedure it is wanting me to configure the CAL-4353 and I don't know how to do that. Any assistance would be greatly appreciated.
PXI-1044 - Problem with analogue input climbing to 10 volts.
I have a NI PXI-1044 containing the following cards:
PXI-6225
PXI-6704
PXI-6511
PXI-6515
I have sensors connected and can read a steady voltage but sometimes the voltage starts climbing to 10 volts. The only way to get it to read the corect steady voltage is to put a volt meter accross the terminals.
Does anyone know what is going on?
If you need more information please ask.
Error -89126: Trigger line requested could not be reserved because it is already in use.
I am trying to control the "PXI_Trig0" using the ctr0 of a DAQ card PXIe-6366.
The trigger will be connected to the input trigger of the scope PXIe-5122 and starting the output generation a FGEN PXI-5412.
The problem is that after several tries the system complains that the PXI_Trig0 is in use when I try to start the crt0 (Error -89126) when this happens the only solution is to turn off the rack and boot again, doing so it works for a while but after some time debugging things the error pops up again.
Is there any way of reseting all the triggers of the rack?
Is there any way of visualize what triggers are reserved in each moment?
Thanks.
What is the specific modelof the connected plug for the PCI4070?
I find that the words of the plug on the User Guide is just 'Banana Plug Connectors' and 'The banana plug connectors are high-voltage, safety signal connectors. '. are there anybody can tell me what is the detailed model? 4mm or 2mm?
LABVIEW FPGA
Am facing problem in compiling a LabVIEW FPGA VI.
I am getting the following error:
You cannot run this VI because the target resource does not match the actual type of the device.
Can anybody help me out of it to fix the error and get the solution.
PXI-6115 RSE Voltage Measurement
I've got a PXI-6115 card and I'd like to make an RSE voltage measurement from input 0, but the only option given to me by DAQmx is pseudodifferential. Is there a way to get past this?
Thanks!
SERDES CLIP in External clock data Acquisition in Flex RIO
Can anyone explain the detailed structure of an SERDES Connector CLIP
in LabVIEW programming Flex RIO.
Additionally,
- How do the acquisition bits get arranged, with respect to each Channel Data?!
- How does the samples to be read considered?!!!
- If I have 16 LVDS Channels, how can I acquire each channels data considering each Lane to reconstruct separately.
Note:
I have seen examples and stuffs related to flex-rio programming but there's no particular explanation for this CLIP, Where things go in deep with high importance.
KT is worth it!! Cause you are storing things permanently in your Brain
Query on PXI 6723 analog output module
Hello everyone
My application requires generation of sinusoidal signals from 0Hz to 18Khz ( having voltage range 50 mVrms to 7 Vrms) . The required resolution & accuracy is 1Hz and 0.1Hz respectively. Will PXI 6723 card can satisfy this requirement?
NI PXI-8196 Controller Upgrade
Hi everyone,
I have a chassis model PXI-1042Q with an embedded controller model PXI-8196.
The system's resources are in the image attached.
I would like to know if there is anything that can be done to improve the system and make it faster (apart from buying a newer controller).The computer and any operation on Labview is really slow.
Thank you.
PXI-4137 Current Limit Response Time
Hello, I am looking for a response time for this module to react to an over-current condition. Thanks for the help
Empty PXI 1045 power consumption
Hi, is there information available about the max. power consumption of the PXI-1045 chassis itself? It seems like it would be drawing some current with its fans at least. I didn't see any specs like this in the manual.
Thanks!
PXIe-1065 not detected by MAX.
Hello,
Need your brain.
I have a PXIe-1065 chassis connected to a PC via a MXI (PXIe-8360, PCIe-8362). MAX sees the PCIe-8362 but doesn't detect the PXI chassis. The PC Device manager also doesn't see the PXI chassis and has a PCI bridge error code 12 "This device cannot find enough resources that it can be used. If you want to use this device, you have to disable another resource in the system". The LINK led on the PXIe-8360 is also off.
This system has worked before. I've tried the correct power sequence - power the PXI chassis before the PC - didn't work. The MXI cable is good and installed correctly. NI PXI Flatform service 14.0 is installed in the system.
What else should I look at?
Thank you.
TestStand CVI Step dll not Loadable. Could not load DLL or external dll
We are using TestStand 2012 to call a cvi dll with the CVI adapter step. We are getting an error that TestStand is unable to load the dll we are trying to call. We verified the dll is good by loading it in LabVIEW with no discrepancies. The error we are receiving is:
Message : Module for Step 'drv_fcx_Init' not Loadable. Could not load DLL or external library 'C:\DMT\CSCI_8026707_FCNS-24\Source\FCNS Fiber Channel\drv_fcx\drv_fcx.dll'.
File : C:\DMT\CSCI_8026707_FCNS-24\Sequences\FCNS_Fiber_Channel_Network_Analyzer.seq
Location : Seq["Open"].Main["drv_fcx_Init"].TS.SData
Rule : Code modules must be able to load
Description : TestStand must be able to load all code modules without error. TestStand reports errors at run time when it
cannot load a code module. Correct this problem by editing the step in the sequence editor.
We were able to get TestStand to load and properly execute the test sequence by switching the step adapter settings by changing the settings:
From:
Execute Steps In-Process (CVI is NOT Required for This Mode) "this did not load the dll"
To:
Execute Steps in an External instance of CVI "this loads the dll and executes the sequence"
Any suggestions on how to fix this discrepancy would be greatly appreciated.
NI PXI/PXIe/DAQmx compatibility with Keysight chassis/controller
Chassis: Keysight M9010A
Controller: Keysight M9036A, Windows 7, Keysight Connection Expert 2018, DAQmx version 15.5
Cards: NI PXI-6509(x2), NI PXIe-4303(x3), NI PXIe-6739(x2)
Host PC: standard Windows 7 PC, DAQmx version 15.5
Host PC and Controller connected over dedicated NICs
Desire is for software on host PC to access PXI(e) cards "through" controller.
Is this a supported configuration?
NI MAX can see PXI(e) cards from controller but not from host. NI MAX doesn't appear to see chassis from either.
PXIe 6356 analog output issue
Hi there, I am trying to run a code where I need to provide voltage to analog output channels 0 and 1 on my SCB-68A connector block, which is connected to the Ni PXIe-6356 terminal block. I am using a digital multimeter to test the voltage that is being provided to the analog output channels. I need to supply 3.3 V to channel 1 and 6 V to channel 0. For some reason, the voltage will not exceed 1.66V on channel 0. Can anyone assist me with this? I'm very new to electronics and I'm not sure if I'm missing some sort of connection or what.
Any assistance is greatly appreciated! Cheers.
Connector Information for PXI-2535
Hi there,
We are using the PXI-2535 Switch Matrix in our chassis. We are using the SHC-68-68 cable for using the 2535. We are looking to develop a customised VHDCI-VHDCI cable.
The SHC68-68 drawing has a VHDCI connector - P/N is 690-68219SF00.
Could someone share the datasheet of this? The manufacturer is listed as Bizconn. This looks to be a customized part.
Best Regards,
Sreekar